简体中文  |  English
MARISEM
  • Home
  • About us
    • Introduction
    • News
    • Contact
    • Feedback
  • Engineering
    • Fluid Control Equipment System Integration
    • Automation Instrumentation System Integration
    • Automation and Control System Integration
    • Bulk/Powder Processing & Handling System
    • Process Control System
  • Maintenance
    • Valve Maintenances
    • Instrument Maintenance
    • Process Control Maintenance and Outsourcing Service
  • Products
    • Valves
    • Valve Actuator and Accessories
    • DCS&PLC Control System
    • Pressure Measurement Instrument
    • Temperature Measurement Instrument
    • Flow Measurement Instrument
    • Level Measurement Instrument
    • Analysis Instrument
    • Field Communicator
    • Low voltage AC drives
  • Brands
    • EMERSON
    • Flowserve
    • Honeywell
    • ABB
    • Siemens
    • Vortex
    • Hach
    • VEGA
    • FCI
    • Ashcroft
    • Barksdale
    • Sartorius
  • Careers
    • Join Us
    • Training Development
    • Benefits Overview

Edit Content Edit Content
Rosemount Vortex Flowmeters
Category: 涡街流量计  Publish Time: 2013-11-19 14:58 

Rosemount Vortex Flowmeters
Rosemount Vortex Flowmeters

Rosemount Vortex Flowmeters allow you to achieve better measurement practices across your applications by eliminating potential leak points, incorporating gasket-free meter body designs that are immune to vibration, and enabling best installation practices with Reducer™ and MultiVariable™ Vortex.

Reducer™ Vortex can save up to 40% per installation by eliminating the need for field installed reducers.

MultiVariable™ Vortex can save up to 30% per installation by eliminating the need for external temperature compensation for saturated steam applications.


Features & Benefits:


Reduced Engineering, Installation and Commissioning Costs

  • Rosemount sizes vortex meters for every application reducing Engineering Costs.
  • Reducer™ Vortex to eliminate the need for field installed reducers
  • Vortex meters can save up to 40% in installation costs over traditional flowmeter installations.
  • Rosemount Vortex Flowmeters arrive pre-configured, hydrostatically tested, and ready to install.


Increased Plant Availability

  • Avoid costly unscheduled shutdowns due to undetected process changes
  • Rosemount vortex features a non-clog meter body that eliminates the possibility of plugged impulse lines or torn diaphragms on remote seals
  • Able to replace sensor without breaking process seals


Reduced Maintenance Costs

  • Eliminates maintenance costs associated with impulse lines such as clogging and purging
  • No periodic recalibration required
  • One spare sensor works for all meters


Increased Safety and Environmental Compliance

  • Gasket-free meter body reduces potential leakp
  • Use Dual Vortex and FMEDA analysis to simplify SIS compliance


Easier verification and troubleshooting through device diagnostics

  • Internal signal generator standard in every vortex for easy electronics verification
  • Able to easily accept an external source
  • Diagnostics along with help are available for easier troubleshooting


Specifications:


Key Specifications

Flowmeter Accuracy

± 0.65 % of rate for liquids
± 1% of rate for gas and steam

Turndown

38:1

Output 

  • 4-20 mA with HART®
  • 4-20 mA with HART® and Scalable Pulse Output
  • FOUNDATION™ fieldbus with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, and 1 Integrator function block (1 PID function block optional)

Wetted Material

Stainless Steel - 316 ⁄ 316L and CF3M
Nickel Alloy- C-22 and CW2M
Consult factory for other wetted material options

Flange Options

ANSI Class 150 to 1500
DIN PN 10 to PN 160
JIS 10K to 40K
Flanges are available in a variety of facings

Operating Temperatures

-330°F to 800°F (-200°C to 427°C)

Line Size

Flanged - ½-in to 12-in (15 to 300 mm)
Wafer - ½-in to 8-in (15 to 200 mm)
Dual - ½-in to 12-in (15 to 300 mm


Applications:


The Rosemount 8800 Vortex Flowmeters are suitable for liquid, gas, and steam applications. The high performance of the Rosemount 8800 Flowmeters solve your toughest flow applications needs by:



  • Eliminating Clogging associated with impulse lines (and other vortex)
  • Reducing potential leakpoints by using a gasket-free meter body design
  • Using a mass balanced sensor and Adaptive Digital Signal Processing to provide vibration immunity
  • Unique isolated sensor design allows replacement without breaking the process seal




  • PVC Plant Reduces Maintenance Costs and Improves Safety with Non-Clog Vortex Technology
  • Vortex Flowmeter Reduces Maintenance Costs and Increases Throughput in Polyester Fiber Production Facility
  • Vortex Technology Improves Plant Safety and Measurement in Chlor-Alkali Electrolysis Cells
  • Coffee Beverage Producer Reduces Maintenance Costs and Improves Reliability with Vortex Flowmeter Technology
  • Leading Oil & Gas Producer Reduced Production and Operating Expenses with Vortex Technology
  • Vortex Technology Improves Fluidized Catalytic Cracker Unit Profits and Performance
  • Vortex Technology Optimizes Alkylate Production at Refineries
  • Vortex Technology Reduces Maintenance Costs and Eliminates Unscheduled Shutdowns in Delayed Coker Applications
  • Paper Mill Improves Quality with Vortex Technology on Supercalender Steam Flow

Prev product:No prev product
Next product:Rosemount 8800 Multivariable Vortex Flowmeter

About Contact Sitemap Feedback

Marisem Industrial Technology Nanjing Co., Ltd. is proud to be a professional supplier for industrial automation products and systems integration solutions.

Copyright @ MARISEM Industrial Technology Nanjing Co.,Ltd. Powered by cxne.com.

Address - Contact > TEL:+86-025-83687688
TEL:+86-025-84319313

关于我们 联系我们 网站地图 举报投诉 法律申明

普维德科工业技术南京有限公司 是一家专业的工业自动化产品及系统集成方案的提供商。业务范围涉及各类自动化产品与系统应用,在石油、化工、电力、冶金、食品、制药、轻工、市政、建材、楼宇等行业拥有丰富的工程经验。

Copyright @ Perwide Industrial Technology Nanjing Co.,Ltd. Powered by cxne.com.

公司地址 - 联系方式 > 电话:+86-025-84578487
传真:+86-025-84578461